CBXRL - PCBS IN SOIL INDIVIDUAL STANDARDS, PS-93 (1248 LOW)

  • MSDS: CBXRL
  • Manufacturer: ENVIRONMENTAL RESOURCE ASSOC
  • Product Name: PCBS IN SOIL INDIVIDUAL STANDARDS, PS-93 (1248 LOW)
  • National Stock Number: 6665-00N072188
Product Identification

Product ID:PCBS IN SOIL INDIVIDUAL STANDARDS, PS-93 (1248 LOW)
MSDS Date:02/19/1996
FSC:6665
NIIN:00N072188
MSDS Number: CBXRL

Responsible Party
ENVIRONMENTAL RESOURCE ASSOC
5540 MARSHALL ST
ARVADA, CO 80002
US

Emergency Phone: 303-431-8454

Info Phone: 303-431-8454

Cage: 1R664

Contractor
ENVIRONMENTAL RESOURCE ASSOCIATES
ARVADA, CO 80002 US

Telephone: 303-431-8454

Cage: 1R664

Ingredients

POLYCHLORINATED BIPHENYL (AROCLOR 1016); (AROCLOR 1016)

CAS: 12674-11-2

RTECS: TQ1351000

Fraction By Weight: <0.05%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POLYCHLORINATED BIPHENYL (AROCLOR 1221); (AROCHLOR 1221)

CAS: 11104-28-2

RTECS: TQ1352000

Fraction By Weight: <0.05%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POLYCHLORINATED BIPHENYL (AROCLOR 1232); (AROCHLOR 1232)

CAS: 11141-16-5

RTECS: TQ1354000

Fraction By Weight: <0.05%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POLYCHLORINATED BIPHENYL (AROCLOR 1242); (AROCHLOR 1242)

CAS: 53469-21-9

RTECS: TQ1356000

Fraction By Weight: <0.05%

OSHA PEL S, 1 MG/M3

ACGIH TLV: S, 1 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POLYCHLORINATED BIPHENYL (AROCLOR 1248); (AROCHLOR 1248)

CAS: 12672-29-6

RTECS: TQ1358000

Fraction By Weight: <0.05%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POLYCHLORINATED BIPHENYL (AROCLOR 1254); (AROCHLOR 1254)

CAS: 11097-69-1

RTECS: TQ1360000

Fraction By Weight: <0.05%

OSHA PEL S, 0.5 MG/M3

ACGIH TLV: S, 0.5 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POLYCHLORINATED BIPHENYL (AROCLOR 1260); (AROCHLOR 1260)

CAS: 11096-82-5

RTECS: TQ1362000

Fraction By Weight: <0.05%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POLYCHLORINATED BIPHENYL (AROCLOR 1262); (AROCHLOR 1262)

CAS: 37324-23-5

RTECS: TQ1364000

Fraction By Weight: <0.05%

OSHA PEL N/K

ACGIH TLV: N/K


POLYCHLORINATED BIPHENYL (AROCLOR 1268); (AROCHLOR 1268)

CAS: 11100-14-4

RTECS: TQ1366000

Fraction By Weight: <0.05%

OSHA PEL N/K

ACGIH TLV: N/K


SOIL; (CLEAN SOIL)

Fraction By Weight: 99.9%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SEVERAL COMPONENTS ARE ANIMAL
POSITIVE, HUMAN SUSPECTED CARCINOGENS. PRIMARY IRRITANT. IRRITATES
AND DAMAGES ALL TISSUES. MAY CAUSE LIVER, KIDNEY AND LUNG DAMAGE.
MAY CAUSE CARDIAC ARRYTHIMIA, MAY SEN SITIZE THE HEART TO
EPINEPHRINE. MAY CAUSE ALLERGIC DERMATITIS OR CHLORACNE. MAY CAUSE
CANCER OF THE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:AROCHLOR 1254:IARC MONOGRAPHS, SUPP, VOL
7, PG 322, 1987:GROUP 2A. AROCOLOR 1254 & 1260:NTP 7TH ANNUAL RPT
ON (SUP DAT)
Effects of Overexposure:HLTH HAZS:LIVER OR HEMATOPOIETIC SYSTEM. SIGNS
AND SYMPTOMS:RED, DRY, SCALY SKIN; CRACKING AND WEEPING SKIN; COUGH
AND WHEEZING. JAUNDICE; NAUSEA AND VOMITING; UREMIA. MAY CAUSE
CHLORACNE.
Medical Cond Aggravated by Exposure:DERMATITIS. LIVER DISEASE, KIDNEY
DISEASE, ANEMIAS AND LEUKOPENIAS.

First Aid

First Aid:INHALATION:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
O*2/ARTF RESP) . EYES:IN CASE OF CONTACT WITH MATERIAL, IMMEDIATELY
FLUSH EYES WITH RUNNING WATER FOR AT LEAST 15 MINUTES. SKIN:WASH
SKIN WITH SOAP AND WATER. REMOVE AND ISOLATECONTAMINATED CLOTHING
AND SHOES AT THE SITE. INGESTION:GIVE SYRUP OF IPECAC 60 CC WITH
180 CC WATER IF SWALLOWED.

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE . NOT
APPLICABLE.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . NOT APPLICABLE.
Unusual Fire/Explosion Hazard:MAY FORM CARBON MONOXIDE, PHOSGENE, AND
CARBONYL BROMIDE IN FIRE (SIGNIFICANT ONLY IF LARGE QUANTITY
INVOLVED).

Accidental Release

Spill Release Procedures:VENTILATE AREA. DAMPEN WITH WATER SPRAY TO
PREVENT DUST DISPERSION. CALL CLEANUP TEAM. DO NOT FLUSH TO DRAIN
OR OPEN WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID BREAKAGE. USE OR STORE ONLY IN
AREAS WHERE SPILLS CAN BE CONTAINED.
Other Precautions:HANDLE WITH CARE! MATERIAL CONTAINS CARCINOGENS.

Exposure Controls

Respiratory Protection:NIOSH APPROVED PARTICULATE OR COMBINED
VAPOR/PARTICULATE FULL FACE RESPIRATOR OR SELF CONTAINED/POSITIVE
PRESSURE FULL FACE UNIT.
Ventilation:LOCAL EXHAUST:USE IN HOOD. SPECIAL:VENTILATE SPILL.
Protective Gloves:VITON OR NEOPRENE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER . CHEMICAL IMPERVIOUS CLOTHING IF LARGE AMOUNTS IN (SUPP
DATA)
Work Hygienic Practices:USE CAREFUL LABORATORY TECHNIQUE. AVOID
CONTACT.
Supplemental Safety and Health
EXPLAN OF CARCIN:CARCINOGENS, 1994:ANTICIPATED TO BE CARCINOGEN.
ANIMAL:LIVER. OTHER PROT EQUIP:USE. LABORATORY COAT, IMPERVIOUS
APRON WITH SLEEVES AND CLOSED SHOES.

Chemical Properties

Spec Gravity:0.889 (H*2O=1)
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR YELLOWISH LIQUID; ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . INCINERATE OR DISPOSE AS HAZARDOUS WASTE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.